LUMENIS VASCULAR IPL Filter

Condition: New
Part #: VASCULAR IPL Filter

$450.00

SKU: VASCULAR IPL Filter Categories: , ,
MAKE AN OFFER
Description

The Lumenis M22 Universal Vascular IPL Filter is a specialized modular component designed to extend the clinical versatility of the M22 multi-application platform. Engineered for precision, this filter narrows the spectrum of Intense Pulsed Light (IPL) to the specific wavelengths required to treat deep-seated and stubborn vascular conditions.

By integrating this filter into the Universal IPL handpiece, practitioners can deliver targeted energy that clears redness and visible vessels while maintaining a high safety profile for the surrounding dermis.


Core Technology: The Power of OPT™

The Vascular filter leverages Lumenis’ proprietary Optimal Pulse Technology (OPT™). Unlike standard IPL systems that can produce “spikes” in energy—leading to potential burns—or “tails” that are sub-therapeutic, OPT™ ensures a uniform top-hat pulse.

  • Precision Control: Allows for the delivery of high peak power in shorter pulses, which is essential for targeting small vessels without overheating the skin.

  • Safety & Efficacy: The consistent energy distribution means fewer passes are required to achieve coagulation, reducing patient discomfort and the risk of side effects.


Mechanism of Action: Selective Photothermolysis

The Vascular filter operates within the 530–650nm and 900–1200nm dual-band range (often colloquially centered around the 590-615nm peak for vascular absorption). It works through the principle of selective photothermolysis:

  1. Absorption: The light energy is specifically absorbed by oxyhemoglobin within the blood vessels.

  2. Transformation: This light energy converts to heat, causing the blood to coagulate and the vessel walls to collapse.

  3. Clearance: Over the following weeks, the body’s lymphatic system naturally resorbs the damaged vessel tissue, leading to a clearer, more even skin tone.


Clinical Applications and Indications

The Vascular filter is specifically indicated for the treatment of both superficial and deeper vascular lesions across Fitzpatrick Skin Types I-V. Key applications include:

  • Telangiectasias: Often referred to as “broken capillaries” or spider veins on the face and chest.

  • Rosacea: Addressing the diffuse background redness and visible flushing associated with erythematotelangiectatic rosacea.

  • Hemangiomas: Treating benign vascular tumors and cherry angiomas.

  • Leg Veins: Effective for smaller, superficial reticular veins (up to 3mm).

  • Poikiloderma of Civatte: Resolving the mottled pigmentation and redness found on the neck and décolletage.


Key Advantages for Practitioners

  • Expanded Patient Reach: Safe for use on darker skin tones (up to Type V) compared to more aggressive laser treatments.

  • Minimal Patient Downtime: Most patients experience only mild redness for 24–48 hours, allowing them to return to daily activities immediately.

  • Seamless Integration: The filter is part of the “Universal” handpiece design, allowing for rapid swaps during a single treatment session (e.g., switching from 515nm for pigment to Vascular for redness).

  • Uniform Results: The lack of energy fluctuations ensures consistent clinical outcomes across different treatment areas.


The Treatment Process

  1. Consultation: Assess the patient’s Fitzpatrick skin type and the depth/diameter of the target vessels.

  2. Preparation: Cleanse the skin and apply a thin layer of chilled coupling gel to facilitate light transmission and protect the epidermis.

  3. Filter Selection: Slide the Vascular filter into the M22 Universal IPL handpiece.

  4. Pulse Delivery: Apply the sapphire cooling tip to the skin. The system delivers controlled pulses based on the selected clinical preset.

  5. Post-Care: Apply a soothing topical or SPF. The patient should avoid direct sun exposure and intense heat for several days.


Technical Specifications & Filter Comparison

The M22 system uses a series of notch filters to customize the light spectrum. The Vascular filter bridges the gap between superficial pigment treatment and deep Nd:YAG laser applications.

Filter / Wavelength Primary Target Tissue Depth Clinical Focus
515nm Epidermal Melanin Superficial Sunspots, Freckles
560nm Mixed Pigment/Vascular Mid-Dermal Sun damage, light redness
VASCULAR Hemoglobin Deep Dermal Spider Veins, Rosacea, Leg Veins
640nm Hair Follicles Deep Hair removal (Skin Types I-IV)

Frequently Asked Questions

What conditions is the Lumenis Vascular IPL filter best suited for?

The Vascular filter is specifically engineered to target hemoglobin, making it the gold standard for treating rosacea, facial telangiectasias (broken capillaries), and cherry angiomas. It is also effective for smaller spider veins on the legs. It focuses energy deeper than the 515nm or 560nm filters to reach vascular structures.

Is the Vascular IPL treatment safe for darker skin tones?

Yes, one of the primary benefits of the Lumenis M22 system is its broad applicability. The Vascular filter is compatible with Fitzpatrick skin types I through V. The system’s OPT™ technology allows for precise energy control, which significantly reduces the risk of post-inflammatory hyperpigmentation in patients with darker complexions.

How many sessions are typically required to see results?

While some superficial vessels may disappear after a single session, most patients require a series of 3 to 5 treatments spaced 4 to 6 weeks apart for optimal clearance. The total number of sessions depends on the severity of the redness and the depth of the vascular lesions being treated.

What does the recovery process look like after a vascular treatment?

The treatment involves minimal downtime. Most patients experience a “sunburn” sensation and mild redness for about 24 to 48 hours. In some cases, treated vessels may temporarily darken or appear bruised before being resorbed by the body. Standard activities can typically be resumed immediately following the appointment.

How does this filter differ from the 560nm filter?

While the 560nm filter is a “versatile” option that addresses both mild pigmentation and superficial redness, the Vascular filter is more specialized. It narrows the light spectrum to more effectively target blood vessels at a deeper dermal level, providing better results for stubborn vascular issues that general filters might miss.

Does the procedure require any form of anesthesia?

Generally, anesthesia is not required. The M22 handpiece features integrated contact cooling, which chills the skin before and during each pulse to minimize discomfort. Most patients describe the sensation as a quick “rubber band snap.” For highly sensitive areas, a topical numbing cream may be applied prior to the session.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.