B. Braun 8719160 Infusion Line

Condition: New
Part #: 8719160

$2,328.00

SKU: 8719160 Categories: ,
MAKE AN OFFER
Description

The B. Braun 8719160 is a specialized, sterile, single-use infusion set engineered for high-precision intravenous therapy. Designed for exclusive compatibility with the Infusomat® Space and SpacePlus large-volume pump systems, this infusion line is a critical component in acute care environments where accuracy and safety are non-negotiable.

Constructed with medical-grade, latex-free materials, the 8719160 minimizes the risk of allergic reactions while maintaining the chemical resistance necessary for a wide range of parenteral medications. Each unit is individually packaged to ensure aseptic integrity from the pharmacy to the bedside.

Core Technology and Safety Features

The B. Braun 8719160 incorporates several proprietary safety technologies designed to mitigate common infusion risks:

  • Anti-Free-Flow Safeguard: An integrated safety clip automatically clamps the line when removed from the pump, preventing accidental bolus infusions or free-flow gravity drainage.

  • Precision Fluid Filtration: A built-in 15µm filter removes particulate matter and air bubbles, ensuring that only pure medication reaches the patient’s vascular system.

  • Anti-Reflux Protection: High-quality valves prevent the backflow of blood or previously infused fluids, maintaining the one-way integrity of the infusion path.

  • Kink-Resistant Tubing: The specialized PVC-free or low-plasticizer tubing maintains a consistent internal diameter even when coiled, ensuring the pump’s pressure sensors provide accurate readings.

Mechanism of Action

The infusion line functions as the mechanical interface between the Infusomat® Space Pump and the patient. When loaded into the pump’s peristaltic mechanism, the pump’s rollers compress the tubing at a calibrated rate.

The 8719160 line is specifically “tuned” to the pump’s pressure sensors. This allows the system to detect upstream and downstream occlusions with high sensitivity. The anti-free-flow clip remains engaged until the pump door is securely closed, at which point the system allows for the programmed flow rate to commence, ensuring total control over the fluid kinetics.

Clinical Applications

This infusion line is versatile enough for use across various clinical departments, including the ICU, NICU, and General Wards. Primary applications include:

  • Total Parenteral Nutrition (TPN): Safe delivery of high-viscosity nutrient solutions.

  • Fluid Replacement Therapy: Precise administration of crystalloids and colloids.

  • Vasoactive Medication Delivery: Accurate micro-infusions of critical drugs where slight rate deviations could impact hemodynamics.

  • Routine IV Antibiotics: Standard medication cycles requiring sterile, reliable access.

Technical Specifications

Feature Specification
Model Number 8719160
Compatibility Infusomat® Space / SpacePlus Pumps
Material Latex-free, DEHP-free (optional variants)
Filter Size 15 µm
Sterilization EO (Ethylene Oxide) Gas
Usage Single-use, Sterile Individual Packaging
Safety Feature Integrated Anti-Free-Flow Clip

Edwards Lifesciences T38F30 Vascushunt II Carotid Shunt

The Edwards Lifesciences T38F30 Vascushunt II is a high-performance silicone carotid shunt designed for use during Carotid Endarterectomy (CEA). During the surgical removal of plaque from the carotid artery, maintaining cerebral blood flow is paramount to preventing intraoperative stroke. The T38F30 provides a secure, atraumatic bypass to ensure continuous perfusion to the brain.

Surgical Design and Technology

The Vascushunt II line is recognized for its “soft-touch” engineering, which prioritizes the integrity of the delicate arterial intima.

  • Medical-Grade Silicone: The shunt is constructed from high-quality silicone that is naturally more flexible than polyurethane, allowing for easier insertion and reduced vessel wall stress.

  • Integrated Safety Balloon: The balloon at the distal end provides secure fixation within the vessel without the need for aggressive external clamping, which can lead to plaque embolization.

  • Flow Control Stopcocks: Integrated ports allow surgeons to flush the shunt, monitor pressure, or draw blood samples without interrupting the primary flow.

Procedural Advantages

The use of the T38F30 in CEA procedures offers several distinct advantages for the surgical team:

  • Sustained Cerebral Perfusion: Minimizes the “clamp time” during which the brain is at risk of ischemia.

  • Atraumatic Fixation: The safety balloon conforms to the vessel’s internal diameter, reducing the risk of intimal dissection or tearing.

  • Kink Resistance: The 30 cm outlying length is designed to loop away from the immediate surgical field, providing the surgeon with an unobstructed view of the endarterectomy site while maintaining a patent lumen.

Technical Specifications

Feature Specification
Model Number T38F30
Diameter 8 French (8 Fr)
Total Length 30 cm
Material Medical-grade Silicone
Configuration Outlying / Balloon-style
Sterility Sterile, Single-use

Why Choose ALLWILL for Clinical Procurement

ALLWILL serves as a strategic partner for healthcare facilities, bridging the gap between global manufacturers and local clinical needs. Our procurement model focuses on three core pillars:

  1. Verified Quality Assurance: Through our Smart Center testing, every B. Braun and Edwards Lifesciences unit is verified for packaging integrity and technical compliance before shipment.

  2. The ALLWILLmatch Platform: We utilize the ALLWILLmatch equipment platform to ensure that the consumables you order are perfectly matched to your existing hardware, eliminating compatibility errors and waste.

  3. MET Supplier Network: Our specialized Logistics and Medical Engineering Technology (MET) network ensures that critical surgical shunts and infusion lines are delivered with the shortest possible lead times, supporting high-volume surgical schedules.


Frequently Asked Questions

Is the B. Braun 8719160 compatible with other brands of infusion pumps?

No, the 8719160 is designed exclusively for use with B. Braun Infusomat® Space and SpacePlus pumps. Using this line with other systems can bypass critical safety features like the anti-free-flow protection and may result in inaccurate flow rates, posing a significant risk to patient safety.

What is the primary benefit of the silicone material in the T38F30 Vascushunt II?

Medical-grade silicone provides superior flexibility and a lower coefficient of friction compared to other plastics. This makes the T38F30 highly atraumatic, meaning it is less likely to damage the delicate inner lining of the carotid artery (the intima) during insertion and removal in CEA procedures.

How does the anti-free-flow safeguard work on the B. Braun infusion line?

The 8719160 features an integrated green safety clip. When the pump door is opened or the line is removed, the clip automatically collapses the tubing, stopping all fluid flow. This prevents gravity-fed over-infusion, a common cause of medication errors in clinical environments.

Can the Edwards T38F30 shunt be re-sterilized for multiple uses?

No, the T38F30 is a strictly single-use device. It is delivered sterile via Ethylene Oxide (EO) gas. Attempting to re-sterilize silicone shunts can compromise the structural integrity of the safety balloon and the lumen, potentially leading to device failure or cross-contamination during surgery.

What is the “outlying” design of the Vascushunt II T38F30?

The “outlying” designation refers to the 30 cm length, which allows the middle section of the shunt to rest outside the surgical incision. This provides the surgeon with a clearer “dry” field to perform the endarterectomy while the blood continues to flow through the shunt.

How does ALLWILL ensure the authenticity of these medical devices?

ALLWILL utilizes a certified procurement channel backed by the ALLWILLmatch platform and Smart Center testing. We track batch numbers and maintain strict cold-chain and storage protocols, ensuring that every B. Braun and Edwards Lifesciences product meets the manufacturer’s original quality and safety specifications.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.