B. Braun 8719145 Infusion Set

Condition: New
Part #: 8719145

$951.00

SKU: 8719145 Categories: ,
MAKE AN OFFER
Description

The B. Braun 8719145 Infusion Set is a premium, sterile, single-use medical device specifically engineered for seamless integration with the B. Braun Space® infusion pump series. Designed to meet the rigorous demands of modern clinical environments, this infusion set ensures the highest levels of precision in intravenous fluid delivery. By combining advanced safety features with user-friendly ergonomics, it serves as a critical component in maintaining accurate therapeutic outcomes for patients undergoing routine and specialized IV treatments.

Core Technology

The 8719145 set utilizes specialized PVC-based tubing (often DEHP-free depending on regional variants) designed to interact perfectly with the peristaltic mechanism of the Space® pump. The core technology centers on its integrated anti-free-flow protection, which automatically prevents accidental gravity flow when the set is removed from the pump. This fail-safe mechanism is vital for preventing medication errors and ensuring patient safety during set changes or pump adjustments.

Mechanism of Action

When loaded into a B. Braun Space® pump, the infusion set’s dedicated pumping segment is compressed and released by the pump’s internal rollers. This controlled movement creates a precise volumetric displacement of fluid. The set’s high-quality material memory ensures that the tubing returns to its original shape consistently, maintaining flow rate accuracy over extended periods. The drip chamber allows for visual monitoring of flow, while the luer-lock connectors provide a leak-proof, secure interface with the patient’s vascular access device.

Applications and Clinical Uses

The B. Braun 8719145 is a versatile solution for a wide range of clinical scenarios, including:

  • Routine IV Therapy: Precise administration of isotonic and maintenance fluids.

  • Medication Administration: Delivery of critical medications requiring exact dosage control, such as antibiotics or analgesics.

  • Fluid Replacement: Management of hydration levels in perioperative and intensive care settings.

  • Continuous Infusion: Stable delivery of fluids in oncology, pediatrics, and general medicine.

Key Advantages

  • Precision Compatibility: Specifically calibrated for the Space® pump series to eliminate delivery variances.

  • Enhanced Safety: Features a latex-free design and integrated anti-free-flow clamps to mitigate allergic reactions and dosing errors.

  • Sterile Integrity: Each set is individually packaged to ensure a sterile fluid path, reducing the risk of catheter-related bloodstream infections (CRBSIs).

  • Efficient Workflow: Designed for rapid priming and easy loading into the pump, saving valuable nursing time.

Technical Specifications

Feature Specification
Model Number 8719145
Compatibility B. Braun Space® Infusion Pumps
Sterility Sterile, Single-use (EO)
Material Latex-free; Medical Grade PVC
Safety Feature Integrated Anti-free-flow Protection
Connection Type Standard Luer-Lock

Edwards Lifesciences T38F30 Vascushunt II Carotid Shunt

The Edwards Lifesciences T38F30 Vascushunt II is a specialized silicone carotid shunt designed for use during carotid endarterectomy (CEA). This high-performance surgical instrument provides a temporary bypass to maintain critical cerebral blood flow while the surgeon removes plaque from the carotid artery. With its 8F diameter and 30 cm length, the T38F30 offers the ideal balance of flexibility and reach, ensuring distal vessel access and reducing the risk of intraoperative stroke.

Core Technology and Design

Constructed from medical-grade, kink-resistant silicone, the Vascushunt II is engineered for durability and tactile feedback. The standout feature is its Safety Balloon Technology, which uses inflatable balloons at either end of the shunt to secure it within the vessel. This eliminates the need for harsh external clamps on the shunt segment, reducing the potential for arterial wall trauma and ensuring the device remains stable throughout the procedure.

Mechanism of Action

During a CEA, the T38F30 is inserted into the common carotid artery and the internal carotid artery, bypassing the clamped surgical site. Once in place, the safety balloons are inflated to create a seal and anchor the shunt. This allows blood to flow through the hollow silicone lumen, providing continuous cerebral perfusion. The integrated stopcocks allow the surgical team to aspirate air or debris and monitor pressure, ensuring the shunt is functioning optimally before the artery is repaired.

Applications and Clinical Uses

  • Carotid Endarterectomy (CEA): The primary use for maintaining blood flow to the brain during plaque removal.

  • Vascular Trauma Repair: Temporary shunting in emergency vascular reconstructions.

  • Ischemic Risk Mitigation: Used in patients with poor collateral circulation (e.g., inadequate Circle of Willis) who cannot tolerate even brief periods of carotid clamping.

Key Advantages

  • Atraumatic Fixation: Safety balloons secure the shunt without the risk of over-pressurizing or damaging the internal carotid artery.

  • Reliable Flow: The kink-resistant design ensures that the lumen remains open even when the shunt is positioned at challenging angles.

  • Intraoperative Control: Integrated stopcocks facilitate blood sampling, air removal, and flow monitoring.

  • Surgical Versatility: The 30 cm length is ideal for cases requiring a longer outlying segment to keep the surgical field clear.

Technical Specifications

Feature Specification
Model Number T38F30
Diameter 8 French (8F)
Length 30 cm
Material Medical-grade Silicone
Fixation Dual Safety Balloons
Components Integrated Stopcocks and Inflation Ports

Frequently Asked Questions

Which infusion pumps are compatible with the B. Braun 8719145 set?

The B. Braun 8719145 is specifically designed for the B. Braun Space® series, including the Infusomat® Space® pumps. Using this set with non-compatible pumps can lead to inaccurate flow rates or the failure of the anti-free-flow safety mechanism. Always verify pump compatibility before clinical use to ensure patient safety.

What is the purpose of the balloons on the Edwards T38F30 Vascushunt II?

The safety balloons serve two main purposes: securing the shunt in the vessel without external clamps and preventing the shunt from migrating during the procedure. They are designed to provide a gentle, atraumatic seal that avoids over-pressurizing the internal carotid artery, thereby protecting the delicate vessel wall.

Is the B. Braun 8719145 infusion set latex-free?

Yes, the B. Braun 8719145 infusion set is 100% latex-free. This makes it safe for use on patients with known latex sensitivities or allergies, reducing the risk of anaphylactic reactions in clinical settings. The materials are selected to be biocompatible and suitable for a wide range of IV therapies.

How does the kink-resistant silicone of the T38F30 benefit the surgeon?

The kink-resistant silicone allows for much easier intraoperative handling. It ensures that even if the shunt needs to be looped or angled to stay out of the surgeon’s way, the internal lumen remains patent. This provides a reliable, uninterrupted flow of oxygenated blood to the brain throughout the surgery.

Can the B. Braun 8719145 set be reused after sterilization?

No, the B. Braun 8719145 is a single-use, disposable medical device. Attempting to resterilize or reuse the set can compromise the integrity of the plastic, lead to mechanical failure of the anti-free-flow protection, and significantly increase the risk of cross-contamination and healthcare-associated infections (HAIs).

What sizes are available in the Vascushunt II product family?

The Vascushunt II family is designed for versatility, offering various diameters and lengths to suit different patient anatomies. Available sizes typically include 8F, 9F, and 11F diameters. In terms of length, surgeons can choose between 15 cm and 30 cm outlying lengths depending on their specific procedural requirements.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.