MEDTRONIC COVIDIEN 7209509 TruCleartm soft tissue shaver plus

Condition: New
Part #: 7209509

$1,100.00

MEDTRONIC COVIDIEN 7209509 TruCleartm soft tissue shaver plus

For other inquiry of this brand, please send us email , we carry all products of this brand.

SKU: 7209509 Categories: ,
MAKE AN OFFER
Description

The Medtronic Covidien 7209509 TruClear™ Soft Tissue Shaver Plus is a high-performance, disposable intrauterine morcellation device designed for the precise removal of intrauterine pathologies. It represents a significant shift in gynecological surgery, moving away from traditional electrical loops toward mechanical resection.

By integrating high-speed cutting with simultaneous aspiration, the TruClear Shaver Plus allows surgeons to treat polyps and fibroids with greater speed and safety. This device is specifically engineered for use within the TruClear Elite Plus and Operative hysteroscope systems, providing a seamless workflow in both hospital operating rooms and ambulatory surgical centers.


Core Technology: Mechanical Morcellation

The TruClear system distinguishes itself through mechanical tissue resection, a technology that replaces the need for radiofrequency (RF) energy.

  • Non-Thermal Action: By utilizing mechanical cutting rather than heat, the device eliminates the risk of thermal injury to the endometrium, preserving tissue integrity for pathology samples.

  • Clear Visualization: Unlike traditional electrosurgery, mechanical morcellation does not produce “bubbles” or smoke, ensuring the surgical field remains clear throughout the procedure.

  • Integrated Suction: Resected tissue is immediately aspirated through the device, maintaining a continuous view of the uterine cavity.


Mechanism of Action

The TruClear Shaver Plus operates through a rotating internal blade housed within a stationary outer cannula.

  1. Tissue Engagement: Controlled suction draws the intrauterine pathology into the 7 mm cutting window.

  2. Resection: The high-speed mechanical blade morcellates the tissue efficiently.

  3. Removal: Resected fragments are instantly transported through the device into a collection canister for histopathological analysis, eliminating the need for manual “fishing” of tissue fragments.


Clinical Applications and Uses

The 7209509 model is the “heavy-duty” workhorse of the TruClear line, optimized for larger pathologies that require high removal rates.

  • Uterine Polyps: Rapid removal of single or multiple polyps of varying sizes.

  • Submucosal Fibroids: Effective management of Grade 0 and Grade 1 myomas.

  • Retained Products of Conception (RPOC): Gentle but efficient removal of post-pregnancy tissue.

  • Large Lesion Management: Specifically indicated when a high tissue removal rate (17 g/min) is required to reduce operative time.


Key Advantages

  • Superior Efficiency: Boasts a removal rate of 17 g/min, significantly outperforming smaller “Mini” versions and reducing total anesthesia time for the patient.

  • Enhanced Safety Profile: The absence of electrical energy reduces the risk of uterine perforation and eliminates the risk of vaginal or cervical burns.

  • Optimized Fluid Management: The system is designed to minimize fluid intrusion, helping to prevent complications related to fluid overload (HYSTEROSCOPIC-related distension media issues).

  • Pathology Preservation: Because the tissue is cut mechanically rather than cauterized, the retrieved samples are of higher quality for lab diagnosis.


Technical Specifications

The Shaver Plus is designed for a balance of reach and power, fitting through standard operative hysteroscopes.

Feature Specification
Model Number 7209509
Outer Diameter 4.0 mm
Cutting Window Length 7 mm
Tissue Removal Rate ~17 g/min
Energy Type Mechanical (Non-thermal)
Compatibility TruClear Elite Plus / Operative Hysteroscopes
Sterility Single-use, Disposable

Frequently Asked Questions

What are the primary benefits of using the TruClear Shaver Plus over traditional D&C?

The TruClear Shaver Plus offers direct visualization of the pathology, whereas D&C is often a “blind” procedure. This allows for targeted removal of polyps and fibroids, reducing the risk of leaving tissue behind. Furthermore, the mechanical morcellation is faster and more precise than manual curettage.

How does the Shaver Plus 7209509 compare to the Shaver Mini?

The Shaver Plus is designed for larger lesions, featuring a 4.0 mm diameter and a 17 g/min removal rate. The Shaver Mini is much smaller (2.9 mm) and slower (4.2 g/min), making it better suited for tiny lesions or diagnostic hysteroscopes with smaller working channels.

Does this device require a specific hysteroscope for operation?

Yes, the TruClear Shaver Plus (7209509) is specifically designed to be compatible with the Medtronic TruClear Elite Plus and other Operative hysteroscopes. It requires a working channel that can accommodate its 4.0 mm outer diameter to ensure smooth entry and effective tissue aspiration.

Why is non-thermal energy important in hysteroscopic tissue removal?

Non-thermal energy is critical for two reasons: safety and sample quality. It eliminates the risk of secondary thermal spread or uterine scarring caused by electricity. Additionally, it prevents “heat artifacts” on the resected tissue, allowing the pathologist to provide a more accurate diagnosis of the removed samples.

Can the TruClear Shaver Plus handle dense fibroids?

The Shaver Plus is highly effective for submucosal fibroids (Type 0 and Type 1). Its high-speed mechanical cutting and 7 mm window allow it to process denser tissue more effectively than diagnostic-sized shavers, though extremely calcified myomas may require longer operative times or specialized morcellation techniques.

How does the system manage fluid and visualization?

The system uses integrated suction to pull tissue into the cutting window and immediately remove it from the cavity. This continuous flow prevents the buildup of blood and debris, ensuring the surgeon has a clear, unobstructed view of the uterine wall throughout the entire resection process.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.