FOTONA G-SET Gynecology GA ( 90°),GC ( 360°) HANDPIECE

Condition: New
Part #: G-SET

$5,000.00

SKU: G-SET Categories: ,
MAKE AN OFFER
Description

The Fotona G-SET Gynecology Kit is a specialized clinical solution designed for Er:YAG laser systems, offering unparalleled precision in non-invasive vaginal health treatments. This comprehensive set features the GA (90°) and GC (360°) adapters, enabling practitioners to deliver highly controlled laser energy for functional restoration and aesthetic rejuvenation.

Engineered for seamless integration with Fotona R11 and PS03 handpieces, the G-SET combines high-performance optics with strict hygiene standards. By utilizing golden-mirror titanium adapters and compatible SClear or MClear speculums, clinics can ensure superior energy reflectivity and patient safety during every procedure.


Core Technology: Er:YAG Laser Integration

The G-SET is built around Fotona’s proprietary SMOOTH® mode technology. This non-ablative Er:YAG modality provides a “feather-like” delivery of laser energy, avoiding the aggressive tissue ablation found in traditional CO2 lasers.

  • 90° Lateral Delivery (GA): Specifically designed for targeted, deep-tissue thermal effects on the vaginal walls.

  • 360° Circumferential Delivery (GC): Enables uniform energy distribution across the entire vaginal canal in a single pass.

  • Golden-Mirror Titanium: The internal adapters utilize premium titanium with gold-mirror coating to ensure 99% reflectivity, maintaining energy consistency throughout the treatment.

Mechanism of Action: Thermal Collagen Remodeling

The G-SET operates by delivering precisely timed laser pulses that heat the vaginal mucosa to a specific temperature range (typically 60-70°C). This controlled thermal pulse triggers two distinct biological phases:

  1. Immediate Tissue Contraction: The heat causes existing collagen fibers to shorten and thicken instantly.

  2. Neocollagenesis: The thermal stimulus activates fibroblasts, leading to the long-term production of new collagen and elastic fibers, which thickens the vaginal wall and improves pelvic floor support.

Applications and Clinical Indications

The G-SET enables the performance of Fotona’s signature gynecological protocols:

  • IncontiLase®: Using the GC (360°) adapter to treat Stress Urinary Incontinence (SUI) by strengthening the anterior vaginal wall and pelvic fascia.

  • IntimaLase®: Utilizing the GA (90°) adapter for non-surgical vaginal tightening to treat Vaginal Relaxation Syndrome (VRS).

  • RenovaLase®: Treating vaginal atrophy and dryness (Genitourinary Syndrome of Menopause) through gentle mucosal rejuvenation.

  • ProlapLase®: Supporting the treatment of pelvic organ prolapse by tightening the endopelvic fascia.


Key Advantages of the G-SET System

Feature Fotona G-SET Standard CO2 / RF Probes
Tissue Impact Non-ablative (No bleeding or scabbing) Often ablative (Risk of scarring/discharge)
Precision Dual 90° and 360° delivery options Usually limited to 360° only
Hygiene Uses disposable SClear/MClear speculums Requires complex sterilization of the probe
Comfort Walk-in, walk-out; virtually painless May require topical anesthesia

The Treatment Process

  1. Preparation: Insertion of the SClear or MClear speculum, providing a sterile environment for the laser adapter.

  2. Adapter Selection: The practitioner selects the GA (90°) for targeted wall work or the GC (360°) for circumferential tightening.

  3. Laser Delivery: The handpiece is moved incrementally along the vaginal canal. Fotona’s SMOOTH® mode pulses heat the tissue without vaporizing it.

  4. Completion: The procedure typically takes 15–30 minutes. No post-operative downtime or antibiotic regimen is required.

Technical Specifications

Specification Details
Compatible Laser Fotona Er:YAG (2940 nm)
Base Handpieces R11, PS03
Adapters Included GA (90° Lateral), GC (360° Circular)
Material Golden-mirror coated Titanium
Hygiene System SClear/MClear speculum compatibility
Pulse Technology Fotona SMOOTH® Mode

Frequently Asked Questions

Which handpieces are compatible with the Fotona G-SET?

The G-SET adapters are specifically engineered for use with the Fotona R11 and PS03 Er:YAG handpieces. This integration ensures that the laser energy is correctly collimated and reflected through the golden-mirror titanium adapters to meet the clinical safety standards of Fotona’s proprietary gynecological protocols.

Is the treatment with the GA and GC handpieces painful?

Treatments utilizing the G-SET and SMOOTH® mode are typically described as virtually painless. Most patients feel a mild sensation of warmth within the vaginal canal. Because the Er:YAG laser is non-ablative, it does not cut or burn the tissue, eliminating the need for anesthesia in most clinical cases.

What is the difference between the GA and GC adapters?

The GA adapter provides a 90° lateral laser beam, which is ideal for precise, targeted treatments like IntimaLase® where specific wall tightening is required. The GC adapter provides a 360° circular beam, allowing for uniform energy delivery across the entire vaginal circumference, which is essential for IncontiLase® protocols.

How many sessions are usually required with the G-SET?

While results can vary based on the patient’s condition, most clinical protocols suggest a series of two to three sessions spaced 4–6 weeks apart. This timeline allows for the full cycle of collagen remodeling and tissue thickening to occur, ensuring optimal functional and aesthetic outcomes for the patient.

What is the downtime after a G-SET gynecological procedure?

There is essentially no downtime. The G-SET procedures are “walk-in, walk-out.” Patients can return to their daily activities immediately. However, most practitioners recommend refraining from sexual activity for 3–7 days to allow the mucosal tissue to settle after the thermal treatment.

Why are golden-mirror titanium adapters used in this set?

Gold-mirror coating provides the highest level of reflectivity for the Er:YAG laser wavelength. By using titanium with this specific coating, Fotona ensures that the laser energy is delivered to the tissue without loss of power or heat buildup within the handpiece, maintaining safety and treatment efficacy.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.