Bard 4030 Inflation Device

Condition: New
Part #: 4030

$1,200.00

SKU: 4030 Categories: ,
MAKE AN OFFER
Description

The Bard Presto™ ID4030 Inflation Device is a premier, single-use manual inflator engineered specifically for high-demand peripheral vascular interventions. Designed to provide clinicians with superior control and power, the ID4030 facilitates the precise inflation and deflation of angioplasty balloon catheters.

In the high-stakes environment of the catheterization lab or vascular surgical suite, the Presto™ ID4030 stands out by offering a unique combination of a 30 cc large-volume barrel and an industry-leading 40 ATM pressure rating. This disposable, sterile device streamlines procedural workflows by eliminating the need for reprocessing while ensuring maximum safety for both the patient and the medical team.


Core Technology and Design

The Bard Presto™ ID4030 incorporates advanced fluid dynamics and ergonomic engineering to handle the rigors of Percutaneous Transluminal Angioplasty (PTA).

  • High-Pressure Fluidics: The internal mechanism is reinforced to withstand up to 40 ATM, allowing for the expansion of high-pressure or non-compliant balloons in calcified lesions.

  • Precision Analog Gauge: The integrated pressure gauge features a high-contrast interface for real-time monitoring, ensuring that the clinician stays within the balloon’s rated burst pressure.

  • Ergonomic Pistol Grip: The handle is designed to reduce hand fatigue during prolonged procedures, featuring a quick-release mechanism for rapid pressure transitions.


Mechanism of Action

The device operates via a manual screw-thread mechanism combined with a rapid-release trigger. When the handle is rotated, the plunger advances within the 30 cc barrel, displacing contrast media or saline through the 17-inch tubing and into the balloon catheter.

The large barrel capacity is a critical technical advantage; it provides enough volume to fill large-diameter peripheral balloons without requiring a refill, maintaining a closed sterile system throughout the procedure. For deflation, the quick-release trigger allows the plunger to be retracted instantly, creating a vacuum for rapid balloon collapse.


Clinical Applications

The Presto™ ID4030 is optimized for a wide range of peripheral vascular procedures where high-pressure dilatation is required, including:

  • Peripheral Transluminal Angioplasty (PTA): Arterial and venous interventions in the iliac, femoral, and popliteal regions.

  • Arteriovenous (AV) Fistula Maintenance: Dilating stubborn stenoses in dialysis access sites.

  • Biliary Stenting: Facilitating the expansion of stents within the biliary duct.

  • Large Vessel Dilatation: Utilizing the 30 cc volume for large-diameter balloons used in the vena cava or aorta.


Key Advantages for the Clinical Team

  • Highest-in-Class Pressure: With a 40 ATM ceiling, this device provides the necessary force to treat even the most resistant, heavily calcified plaques.

  • Enhanced Safety Profile: Provided EO (Ethylene Oxide) sterile, this single-use device eliminates the risk of cross-contamination and simplifies post-procedure cleanup.

  • Workflow Efficiency: The 17-inch extension tubing and standard Luer lock ensure seamless connectivity with all major balloon catheter brands, reducing setup time.

  • Superior Tactile Feedback: The ergonomic grip provides the physician with immediate feedback, allowing for subtle adjustments in inflation speed and pressure.


Technical Specifications

Feature Specification
Max Pressure Rating 40 ATM (588 PSI)
Barrel Volume 30 cc
Tubing Length 17 Inches (43 cm)
Connector Type Rotating Male Luer Lock
Sterilization Ethylene Oxide (EO)
Configuration Pistol-Grip Manual Inflator
Gauge Type Integrated Analog

Frequently Asked Questions

What is the maximum pressure capacity of the Bard Presto™ ID4030?

The Bard Presto™ ID4030 is engineered for high-pressure performance, offering a maximum pressure rating of 40 ATM (atmospheres). This makes it one of the most powerful manual inflation devices in its class, specifically designed to handle non-compliant balloons and complex peripheral cases where standard inflators may fall short.

Why is the 30 cc barrel volume significant for vascular procedures?

The 30 cc large-volume barrel allows clinicians to inflate even large-diameter peripheral balloons with a single fill of contrast or saline. This eliminates the need for mid-procedure refills, which can introduce air bubbles or contamination, thereby increasing procedural efficiency and maintaining a safer, closed sterile environment during angioplasty.

Can this inflation device be reused after sterilization?

No, the Bard Presto™ ID4030 is strictly a single-use, disposable device. It is delivered EO (Ethylene Oxide) sterile and intended for use on a single patient only. Attempting to re-sterilize or reuse the device could compromise its structural integrity, particularly the high-pressure seals, and poses a significant risk of cross-contamination.

How does the ergonomic handle improve procedural outcomes?

The ergonomic pistol-grip design is built for precision and comfort. It allows for a steady, controlled increase in pressure, which is vital for preventing vessel trauma. The quick-release trigger mechanism also enables near-instant deflation, which is critical for restoring blood flow as quickly as possible after balloon expansion.

Is the Bard Presto™ ID4030 compatible with all balloon catheters?

Yes, the device features a standard 17-inch extension tube with a rotating male Luer lock. This universal connectivity ensures that the Presto™ ID4030 is compatible with virtually all standard angioplasty balloon catheters and interventional equipment, allowing it to be easily integrated into any existing cath lab or surgical inventory.

What is the primary benefit of the integrated analog gauge?

The integrated analog gauge provides clear, real-time visual monitoring of internal pressure levels during inflation. This is essential for procedural safety, as it allows the clinician to accurately reach the balloon’s nominal pressure and avoid exceeding the rated burst pressure, ensuring a controlled and predictable vessel dilatation.

Listing Terms & Conditions

We ship worldwide, please inquire the shipping rate to your country before placing an order.

We carry all products of this brand in the listing, please let me know if you have any other inquires which is not listed in our store.

All purchases over $1,000 must be paid by wire transfer. We cannot accept international credit card payments for orders over $1,000.

Due to worldwide shipping delays, it is possible that items listed could be on backorder. If the item is unavailable for an extended period, we sincerely apologize for the delay. In this case, we will refund you as soon as we are notified of the backorder and contact you with the confirmation of refund.